The following types of hot water systems meet the Full Standard:

1. A Natural Gas or LPG hot water system (instantaneous, continuous flow or storage) that has:

2. An Electric Boosted Solar or Heat Pump hot water system, that:

Hot Water Load
Tank Volume in Litres (L)
Minimum RECs in ORER Zone 3*
Single Tank System
Multi Tank System
Small Tank volume equal to or less than 220 L Preheat tank volume equal to or less than 110 L 18 RECs
Medium Tank volume greater than 220 L and less than 400 L Preheat tank volume greater than 110 L and less than 200 L 28 RECs
Large Tank volume equal to or greater than 400 L and equal to or less than 700 L Preheat tank volume equal to or greater than 200 L and equal to or less than 350 L 40 RECs
* REC levels are based on Office of the Renewable Energy Regulator (ORER) Zone 3, regardless of the actual zone in which the water heater is installed.

3. A Gas Boosted Solar hot water system that:

4. A Wood Combustion hot water system with:

5. A Wood Combustion Boosted Solar hot water system with:

Note:
Gas Water Heaters
Energy ratings for natural gas and LPG water heaters can be found at:
http://www.aga.asn.au/product_directory

Solar and Heat Pump Water Heaters
The number of renewable energy certificates (RECs) is provided for each eligible model of solar water heater and heat pump water heater at:
http://www.orer.gov.au/publications/swh-register.html

Other Water Heaters
The SA Water Direction specifies a Performance Verification Method that can be used to demonstrate compliance with the Full Standard for water heaters not listed above.